To Configure the Pressure Input The Power Commander V has an analog voltage input. This input can be used with a 0-5V pressure sensor. 1 Select Power Commander Tools Configure Pressure Input. 2 Select the Enabled box. 3 Using the drop-down arrow, choose the number of columns you wish to display. 4 Using the information provided with your sensor, enter the voltages and display values. For example: 0.5V=0 psi, 4.5V=50 psi. 5 Click OK to accept the changes. Or Click Cancel to close the window without changes.